<1 Hr Actions Flashcards
DNBR > 1.14
Fuel Centerline Temp > 5080 F
2.1.1 Reactor Core SLs
Mode 1 and 2
Restore compliance and be in Mode 3
1 Hr
RCS Pressure > 2733.5 psig
2.1.2 RCS Pressure SL
Mode 1, 2, 3, 4, and 5
In Mode 1 or 2: Restore compliance and be in Mode 3
1 Hr
In Mode 3, 4, or 5: Restore compliance
5 minutes
One or more RTS Manual Actuation Functions with two manual actuation channels inoperable
3.3.5 RTS Manual Actuation
MODE 3, 4, or 5
Initiate action to fully insert all rods
AND
Place the PCS in a condition incapable of rod withdrawal.
1 Hr
One or more required DC Electrical Power Subsystems Inoperable
3.8.2 DC Sources (Shutdown)
MODES 5 and 6,
During movement of irradiated fuel assemblies
Declare affected required features inoperable
Immediately
OR
Suspend movement of irradiated fuel AND Suspend operations with a potential for draining Rx AND Suspend operations involving positive reactivity additions that could result in loss of SDM or boron concentration AND Initiate action to restore to operable Immediately
One or more required inverters inoperable
3.8.4 Inverters (Shutdown)
MODES 5 and 6,
During movement of irradiated fuel assemblies
Declare affected required features inoperable
Immediately
OR
Suspend movement of irradiated fuel AND Suspend operations with a potential for draining Rx AND Suspend operations involving positive reactivity additions that could result in loss of SDM or boron concentration AND Initiate action to restore to operable Immediately
Two inoperable divisions that result in a loss of safety function
3.8.5 Distribution Systems - Operating
MODES 1, 2, 3, and 4
Enter LCO 3.0.3
Immediately
One or more required DC or AC instrumentation and control bus electrical power distribution subsystems inoperable
3.8.5 Distribution Systems (Shutdown)
MODES 5 and 6,
During movement of irradiated fuel assemblies
Declare affected required features inoperable
Immediately
OR
Suspend movement of irradiated fuel AND Suspend operations with a potential for draining Rx AND Suspend operations involving positive reactivity additions that could result in loss of SDM or boron concentration AND Initiate action to restore to operable Immediately
One or more batteries in one division with one or more battery cells float voltage < 2.07 V and float current > 2 amps
3.8.7 Battery Parameters
When associated DC electrical power sources are required to be OPERABLE
Declare associated battery inoperable
Immediately
One or more penetration flow paths with 2 containment isolation valves inoerable
3.6.3 Containment Isolation Valves
MODES 1, 2, 3, 4
Isolate affected penetration flow path by use of at least one closed and deactivate automatic valve, closed manual valve, or blind flange.
1 Hr