1-B-4 High Rise Fires Flashcards
Even with optimum positioning 100 foot aerials are limited in reach too about the ________ floor
8th
When practical, aerial apparatus should be ________ into position
Backed
Ventilation should be prioritized as follows:
- apartments and/or floor with a known life hazard
- the fire apartment and / or floor
- General smoke removal from the entire structure beginning with the lowest smoke-filled floor
For small fires with a limited amount of smoke production, consideration should be given to utilizing natural ventilation or ________
Electric fans
________ is a unit established at high-rise incidents to assist the IC with the accountability of personnel, control of building systems, Control and direction of evacuees, And logistical support
Lobby control
Lobby control is often assigned to the first arriving ________
Rescue
Use of non-fireman’s service elevators is permitted only if the car doesn’t serve ________
The fire floor
________ is a procedure that may be employed for the rare situation of a fire located in the upper stories coupled with nonfunctioning or unsafe elevators
Stairwell support
Cruise should refrain from using elevators if the fire was on or below the ________ floor or if the safety of the elevator is in question
6th
If the elevator is used prior to a dedicated elevator operator being assigned from lobby control, one firefighter must assume the position of ________
Elevator control firefighter
Cruise should exit the elevator ________ floors below the fire floor and walk up the stairs
1 to 2
When available, the use of ________ should be considered to simplify communications within the building and reduce radio traffic
In-house communications