1-36 Flashcards
Who is or can be in charge.
Overall responsibility for compliance with API 653
owner
1.2
Evaluate deterioration on existing shell material
Engineer
4.3.1.2
In a corroded area, find t2 (thinnest area exclusive of pit)
Inspector
4.3.2.1.a
In a corroded area, determine the vertical lines (L)
Inspector
4.3.2.1.c
Perform the Routine In-Service inspection
Operator
6.3.1.1
Perform the External inspection
Owner
6.3.2.1
Determine the extent of UT measurements not he shell
Owner
6.3.3.1
Review the results of CP surveys
Owner
6.3.4.1
Assure competency of personnel performing CP surveys
Owner
6.3.4.2
Perform the Internal inspection
Inspector
6.4.1.2
Assure quality and completeness of in-service NDE (robotics) examinations
Inspector AND NDE Guru
6.4.1.2
Determine internal interval based on tank bottom corrosion
Owner
6.4.2.3
Determine internal interval based on RBI
Owner
6.4.2.4
Conduct an RBI assessment
RBI Guru
6.4.2.4
Review and approve RBI assessments
Inspector AND Engineer
6.4.2.4
Maintain tank records
Owner
6.8.1
Review inspection findings and recommendations
Owner
6.9.3.2
Ensure disposition of all recommended repairs and monitoring
Owner
6.9.3.2
Evaluate and accept NDE examination results
Inspector
6.10
Authorize all repairs
Inspector Or Engineer
9.1.3
Authorize all alterations
Engineer
9.1.3
Designate inspection hold points for repairs, alterations & reconstructions
Inspector
9.1.3
Provide general authorization for limited routine repairs
Inspector
9.1.3
Approve all proposed methods of design, materials, WPSs, NDE & testing
Inspector Or Engineer
9.1.4