Water damage course 46-75 Flashcards

1
Q

In an area that measures 15,000 cubic feet, what is the initial recommended AHAM requirement (PPD) for a Class 2 loss, using LGR (refrigerant) dehumidifiers?

A

300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A Class 3 loss that measures 15’ x 35’ and has a ceiling height of 9’, how many 100-pint LGRs are needed?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A warehouse that measures 35’ x 40’ x 10’ has a class 4 loss, using a desiccant dehumidifier. How many CFM are required?

A

700 cfm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

To help control particles in the air you could install

A

An air filtration device (AFD)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Generally, to dry the wood subfloor under a resilient floor (e.g., sheet vinyl, VCT, LVT, LVP), what should a restorer do?

A

Remove vinyl to access and dry the subfloor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If you decrease GPP what happens to the vapor pressure? – SHOW ON PSYCH

A

Decreases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A hardwood floor primarily absorbing moisture from the bottom and the sides of the boards are higher than the center. This is referred to as

A

Cupping

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When arriving on a water loss that has an elevated humidity; if the outside conditions are right, what could be done to reduce the humidity?

A

Open the windows to ventilate the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens when air reaches saturation?

A

Condensation because the air can’t hold more water vapor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When could a closed drying system be utilized?

A

When the Humidity Ratio outside is higher than the GPP indoors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens when the vapor pressure of wet materials is increased?

A

Moisture evaporates if the ambient air has a lower vapor pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

To determine the amount of dehumidification necessary, the following information is needed:

A

Cubic footage, class of loss and type of dehumidifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Why should air movers not be installed when microbial growth is found or suspected?

A

It can contaminate other areas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is evaporation?

A

Changing liquid to a vapor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is vapor pressure?

A

The force from water vapor in the air on surrounding materials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What results as the air becomes warmer (temperature increases)?

A

Relative humidity decreases

14
Q

When drying a hardwood floor, typically we will need to?

A

Allow for acclimation and refinishing after the floor is dry

15
Q

If insulation is affected by water, what would be the typical response?

A

Remove the insulation to access and dry structural materials

16
Q

What is the primary function of a dehumidifier?

A

Reduce the water vapor in the air

17
Q

Why are desiccant dehumidifiers often used in Class 4 losses?

A

They create the lowest vapor pressure of any type of dehumidifier

18
Q

How often should a job site be monitored?

A

every day

18
Q

If thermal energy is added to affected materials

A

Evaporation increases

19
Q

If humidity remains high, what can happen to hygroscopic materials?

A

Secondary damage can occur

20
Q

If plywood is affected by water damage

A

It can typically be dried and restored

20
Q

In a drying chamber with the conditions of 75°F and 65%RH, at what temperature could condensation form on materials?

A

62°F

21
Q

Which of the following is a vapor barrier/retarding material?

A

Vinyl flooring

22
Q

Why are low grain refrigerants (LGR) generally more efficient than a conventional refrigerant?

A

They create lower vapor pressure

23
Q

A material that is very weakened when wet but, if dried properly, retains its original strength is

A

Gypsum (drywall, wallboard)

24
Q

What is permeance

A

The rating of vapor passing through a material

25
Q

If attempting to dry tile over a wood subfloor

A

Increase heat or thermal energy