PV System Electrical Design Flashcards
Use this deck to learn about all of the electrical design aspects of a PV system installation.
Suppose an alternate series three-stage charge controller is available as a backup to a parallel three-stage PV charging source such as a utility-interactive battery-based inverter. Also assume that the PV source is intended to be the dominant charging source. How could one ensure that the PV source is the dominant charging source?
Set the bulk voltage of the PV charging source lower than the float voltage of the alternate controller.
The lowest anticipated air temperature must be correct in order to determine what?
The expected maximum PV array voltage
When searching for the cause of a PV system failure, at which step would you check the shorted solar cells?
Last step
Assume the STC maximum-power voltage of a crystalline silicon PV array is 68.4 V. The irradiance is 800 W/ m2 and the module temperature is 50 degrees C. Assuming the inverter is tracking maximum power with a 1.6% voltage drop between modules and inverter input, what should the inverter input voltage be closest to?
58.9 V
What is the formula used to find voltage drop?
V = IR
Volts = Amperes * Resistance
A single inverter system requires 9 or 10 modules in series and one or two series strings in parallel. If the southeast roof is large enough for 8 modules and the southwest roof is large enough for 15 modules, what array configuration results in the most efficient use of the PV modules installed?
10 modules on southwest roof and 0 modules on southeast roof
Is the DC disconnect between the panel and the inverter?
No
What natural factor inhibits higher voltages in PV?
Hot weather
What does a self-regulating PV system NOT have?
A charge controller
What type of weather does NOT inhibit higher voltages in PV?
Cold weather
What happens when the current exceeds that which is determined by the equivalent resistance in the network?
A short circuit
To determine the expected maximum PV array voltage, the module voltage at Standard Test Conditions (STC) must be corrected to what?
The lowest anticipated air temperature
What is the effect on voltage drop of a higher volt system?
A lower percentage of voltage lost due to resistance
What capability of a 500 V DC PV array gives it an advantage over a 48 V DC PV array of the same wattage?
Smaller conductors can be used between the array and inverter
During the critical design month in the worst case scenario, what is NOT used to size the PV system?
Total power demand, peak demand, and duty cycle