Week 5: Save on Foods Collapse Flashcards
1
Q
What two modes of failure were involved in the roof collapse?
A
- Beam failure: primary cause of failure - beam was under strength for imposed bending loads (negative bending over column), and laterally unsupported lower compression flange of the beam buckled at supporting column
- Column failure: vertical beam-column assembly buckled simultaneously - though probably not primary cause
2
Q
T/F: The recommendations made by the Closkey report were implemented right aways
A
False: Many took decades to implement
3
Q
What 5 categories can the 19 recommendations made by the report be put into?
A
- Implementation (task force)
- Technical
- Building regulations and inspectors
- Construction industry procedures
- Engineering standards
4
Q
List 5 of the 9 actions that led to the roof collapse
A
- change in slab thickness
- extra concrete in walkway
- smaller beam used
- mill coupon certificates incorrectly done (from web and not flange)
- no buckling resistance in beam and column
5
Q
List the sequence of collapse of the beam/column assembly
A
- column head displaces laterally
- lower beam flange yields
- web begins to buckle
- joists begin to disconnect
- displacement and buckling increase until joists fail
- collapse immediate
6
Q
What are 3 of the 19 recommendations made in the Closkey report?
A
- Structural engineers to pass special exam
- monitoring of structural drawings and calculations as part of building permit application
- register engineering companies