PRAC Questions Flashcards

1
Q

Which wall would be more subject to light and glare issues?
North, East, South, or West

A

South wall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does the IBC say about walls in restrooms?

A

public toilet and bathing rooms must have smooth, hard, nonabsorbent surfaces to a height of not less than 4 feet (1219 mm) above the floor.

Walls must also have smooth, hard, nonabsorbent finishes at certain distances around urinals and water closets and surrounding shower and tub compartments. This can be accomplished with ceramic tile as well as other applied vinyl or plastic coverings.

cement board is best for a substrate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

To allow for acoustical privacy, should walls be taken to the ceiling, 4” past the ceiling, or to the deck?

A

to the deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where would you place the access panel for an AHU (air handling unit)

A

AHU access panels can go either directly underneath or adjacent to the unit where ductwork does not connect to the unit. In this case the symbol is showing the location of access, because a ceiling tile will be removed. The location should fit within the ceiling grid, and not conflict with other elements such as lighting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

in what section/table can you find information about fire-rated doors in relation to fire-rated walls?

A

IBC Chapter 7 table 716.1(2)

if there is a corridor and other suite enclosure walls specified to be 1-hour rated, it would make the door 1/3 hour or 20 minutes fire-rated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the minimum dimensions for a clear space below an accessible dining counter?

A

27”h X 30”w x 17”d

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is accessible shower seat height?

A

17”min - 19”max

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Typical dining seat dimensions (dining chairs and barstools)

A

Dining Chairs: 17-22”d x 14”-20”w X 18”h
Barstools: 30”-34”h

Generally seat height is 12” below table or worksurface

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When the partition is fire-rated, what type of hardware is required for the door?

A

A closer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is AFCI protection required?

A

dwelling unit kitchens, family rooms, dining rooms, living/parlor rooms, bedrooms, sunrooms, rec rooms, closets, hallways, laundry, and similar areas

USB outlets do not require AFCI unless paired with outlet of normal amperage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the outlet spacing requirement for residential spaces per NEC?

A

outlets should be located so that no point along the floor line is more than 6 feet from an outlet. (from the middle)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What appliances require 240v outlets?

A

dishwasher
range
washer
dryer
hot water heater
air handler unit

if the appliance is gas powered, usually it requires a 120v for the pilot light

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the accessible height of dining and work surfaces?

A

28” min and 34”max

(ICC A117.1 902.4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What chapter and section talks about maneuvering clearances in the ICC A117.1?

A

Chapter 3 section 305

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does ANSI/BIFMA X5.9 do?

A

Provides current test methods for freestanding, moblie, and wall-mounted storage units. this also covers vertical and lateral units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What spaces could benefit from a daylight sensor?

A

All occupied spaces within 15’ of an exterior window

17
Q

Where would you place a manual control or light reduction control function?

What is a light reduction control function?

A

provide in areas with time-switch controls – not in areas where occupant sensors are used

it is when you can control which lights are on and which are off. For example, select every other light trough to be on instead of all of them.

IECC C405.2.1

18
Q

What is the maximum accessible height for a sales/service counter?

A

36” max (minimum length is 30”)

19
Q

What is the height for electrical receptacles

A

18” AFF unless noted otherwise

20
Q

What is the clearance needed in front of an electrical panel?

A

36”

21
Q

a vertical change in the floor finish cannot exceed what height without a sloped transition?

A

1/4”

22
Q

Where should exit signs be placed?

A

Over doors, corridors, and at changes of direction

Wall-mounted over doors
Ceiling mounted in corridors

always refer to the program

23
Q

Where should smoke detectors be placed?

A

in each room, corridor, or area separated by partitions

Always refer to the program and look at the exhibit

24
Q

Where would you place emergency lights?

A

In an area that needs to be illuminated to exits. corridors and exits pathways and exit doors

A bathroom does not need an emergency light unless it exceeds 300sf

25
Q

Where would you place audio/visual alarms?

A

spots that would allow to be visible from any area of the room or space

26
Q

How would you place dimension lines/centerlines?

A

pull away from fixture for readibility

27
Q

How many grab bars are required for a roll-in shower?

A

2 grab bars are required

28
Q

what are the steps or the thinking process you would take when placing receptacles in a kitchen?

A
  • All appliances require an outlet (240v for range/oven and dishwasher)
  • Outlet required for each section of countertop 12” or wider. No more than 24” between outlets
  • Provide convenience outlets on either side of the sink
  • all outlets, even in the island must be GFCI

Look at the exhibit and program

29
Q

Should Xenon and LED be switched separately?

A

yes

30
Q

Where would required clearances be placed in a floor plan?

A

1.) provide turning circle at changes in direction
2.) Show corridor dimensions or path off travel
3.) show push/pull dimensions at interior doors in accessible spaces or path of travel

31
Q
A
32
Q
A