Which wall would be more subject to light and glare issues?
North, East, South, or West
South wall
What does the IBC say about walls in restrooms?
public toilet and bathing rooms must have smooth, hard, nonabsorbent surfaces to a height of not less than 4 feet (1219 mm) above the floor.
Walls must also have smooth, hard, nonabsorbent finishes at certain distances around urinals and water closets and surrounding shower and tub compartments. This can be accomplished with ceramic tile as well as other applied vinyl or plastic coverings.
cement board is best for a substrate
To allow for acoustical privacy, should walls be taken to the ceiling, 4” past the ceiling, or to the deck?
to the deck
Where would you place the access panel for an AHU (air handling unit)
AHU access panels can go either directly underneath or adjacent to the unit where ductwork does not connect to the unit. In this case the symbol is showing the location of access, because a ceiling tile will be removed. The location should fit within the ceiling grid, and not conflict with other elements such as lighting.
in what section/table can you find information about fire-rated doors in relation to fire-rated walls?
IBC Chapter 7 table 716.1(2)
if there is a corridor and other suite enclosure walls specified to be 1-hour rated, it would make the door 1/3 hour or 20 minutes fire-rated
What are the minimum dimensions for a clear space below an accessible dining counter?
27”h X 30”w x 17”d
What is accessible shower seat height?
17”min - 19”max
Typical dining seat dimensions (dining chairs and barstools)
Dining Chairs: 17-22”d x 14”-20”w X 18”h
Barstools: 30”-34”h
Generally seat height is 12” below table or worksurface
When the partition is fire-rated, what type of hardware is required for the door?
A closer
Where is AFCI protection required?
dwelling unit kitchens, family rooms, dining rooms, living/parlor rooms, bedrooms, sunrooms, rec rooms, closets, hallways, laundry, and similar areas
USB outlets do not require AFCI unless paired with outlet of normal amperage
What is the outlet spacing requirement for residential spaces per NEC?
outlets should be located so that no point along the floor line is more than 6 feet from an outlet. (from the middle)
What appliances require 240v outlets?
dishwasher
range
washer
dryer
hot water heater
air handler unit
if the appliance is gas powered, usually it requires a 120v for the pilot light
What is the accessible height of dining and work surfaces?
28” min and 34”max
(ICC A117.1 902.4)
What chapter and section talks about maneuvering clearances in the ICC A117.1?
Chapter 3 section 305
What does ANSI/BIFMA X5.9 do?
Provides current test methods for freestanding, moblie, and wall-mounted storage units. this also covers vertical and lateral units