Oxygen System Flashcards

1
Q

Where is the LOX convertor and what is it enclosed in

A

Mounted in right side of nose wheel well, enclosed in removable fiberglass cover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What side must you enter and exit the nose wheel well from and why

A

Left side, there is a hazard of venting LOX on the right

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where can you see the qty of remaining LOX

A

Bottom of the HDD system status page

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where are low oxygen quantities indicated

A

ACAWS messages on the HDD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How is oxygen brought to cabin temperature

A

It is routed through the heat exchanger and warmed by ambient air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where is the gaseous shutoff valve located

A

Mounted on right side of fwd bulkhead (secured in open position)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is between the supply & demand sides of the oxygen system

A

The oxygen flow shutoff valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many diluter-demand automatic pressure breathing regulators are located throughout the aircraft

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What position must the emergency toggle lever remain to avoid rapid oxygen depletion

A

NORMAL position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which component turns off the flow of oxygen prior to the individual distribution lines

A

Oxygen manual shutoff valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the minimum number of quick Don masks provided during a mission

A

5 (2 in cockpit)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many portable oxygen bottles are on board

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What range of LOX will be in the LOX QTY message (yellow) range

A

2.5-5.0L

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What range if LOX will be in the LOX QTY ALERT message range (red)

A

Below 2.5L

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How is actual operational hours of oxygen calculated

A

Divide the number found on diluter lever - normal chart and divide by number of personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is indicated pressure in a static system under a no flow condition and under continuous breathing condition?

A

270-455 PSI and 270-340 PSI