Nate Heat Pumps Flashcards

1
Q

Heat can neither be _____ or _______.

A

created, destroyed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Heat moves from _____ to _____.

A

hot, cold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Boiling point of a substance is proportionall related to the ______ it is under. The higher the pressure, the higher the ____ _____.

A

pressure, boiling point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

suction pressure is also called low pressure and______ ____

A

back pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

5 compressors used in hvac are

A
1- scroll
2- reciprocating
3- screw
4- rotary
5- centrifugal
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

compressor with fewest moving parts made in the late 1980s. Compresses vapor volume into smaller and smaller area.

A

scroll: orbiting scroll moves and fixed scroll doesnt move.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

which compressor are not designed to handle liquid refrigerant.

A

scroll and recipricating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

In a single phase motor an overload is either internal between the _____ and common windings. overload can also be on the same motor externally mounted.

A

start, run

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Never take resistance reading directly on compressor terminals. Always use _____ ______ instead. Safety precaution.

A

wire leads.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If reading an open circuit between c and windings always _____, connections are ____and _____ hasnt burned off. Check continuity of the wires as well

A

visual inspection of terminals, tight, common wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Causes of an open internal overload are

A
  • low refrigerant/ ineffient cooling of the compressor.
  • excessive refrigerant charge/ too much load/ amps/heat.
  • non condensables/ air in the superheated gas in suction line and discharge line causing no refrigerant cooling of compressor.
  • excessive air flow can cuase too much superheat, in efficient cooling of compressor.
  • low/no airflow at condenser/ no subcooled refrigerant at metering device/ excessive super heat, no cooling of compressor.
  • failing/failed capacitor.

-

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

line wire must be sized by guage and length to handle ______

A

minimum circuit ampacity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Make sure the _______ panel is the proper sized to handle all _____ within the structure.

A

breaker, loads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If there are complaints of dimming lights check all wire _______ are clean and _____ between the breaker to the compressor terminals.

A

connections, tight.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly