State the function of the Fire Protection System.

A

The function is to protect plant equipment, structures, and personnel from fire or explosion.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

TRUE/FALSE
The Fire Protection System utilizes smoke detectors for alarm functions and heat detectors to activate suppression systems

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The operator would depress which one of the following control panel keys on the Network Control Annunciator in the control room to acknowledge a fire alarm.

a.	Signal Silence/Scroll Display.
b.	Fire Alarm/Scroll Display.
c.	Trouble/Scroll Display.
d.	System Reset.
A

b. Fire Alarm/Scroll Display.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

TRUE/FALSE
All smoke detector zones contain two redundant strings, A and B, with the exception of zone 4 and zone HSCP-1, having only one string each.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What must the operator ensure before a fire alarm can be reset at either the Network Control Annunciator or the Master Remote Control Panels?

A
  1. The condition causing the alarm must be corrected.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State the function of the Meteorological System Instrumentation.

A

The function of the on-site meteorological instrumentation is to provide atmospheric information for postulated accidental and routine airborne releases of effluents.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How does the Met Tower transmit data to the control room?

A

The Met Tower transmits data to the Control Rooms via VHF radio transmission to antennas located on the 43 foot level of the RAB.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

List the parameters the Met Tower monitors, and at what elevations the data is collected.

A

The parameters monitored by the Met Tower are air temperature, wind direction and wind speed. The data points are located at 10 meters and 57.9 meters. Also monitored are differential air temperature between 10M and 57.9M, intake and discharge canal temperatures and discharge canal level. The temperature monitoring point at 33.5 meters is not used by the control room.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A gas release is ready to be performed. Which Met Tower channels must be operable, and how are they verified to be operable?

A

Wind direction, wind speed and air temperature at 10M and also air temperature at 57.9M are required to be operable. Verification that all channels are operable can be done by observing the Multipoint Recorder/Logger behind RTGB 101 to ensure all channels are tracking properly on the chart or by reviewing the 24 hour graph on the DCS monitor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Describe the basic operation of the loose parts monitor detector.

A

The LPMS monitors the reactor coolant system (RCS) for internal loose parts. The system is designed to detect a loose part striking the internal surface of RCS components. The accelerometers are able to detect the mechanical vibration propagating from the point of impact and convert it into an electrical signal which is amplified in the system pre-amp, processed by the loose parts data acquisition system and recorded by the LPM computer.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

List the location of the eight loose part accelerometers.

A

a) Two at both steam generators
b) Two at the head of the reactor
c) Two at the bottom of the reactor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the surveillance interval of the loose parts monitor channel check?

A

Daily

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If the loose parts monitor were to be in alarm, where would the most affected channel be displayed?

A

The most affected channel will be located at the top of the upper display window of Waveform Screen (6/7).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are the two inputs that cause the loose parts monitor to alarm on the RTGB?

A

Critical Failure and Loose Parts