LOT 110.01 Operating Limits Flashcards
- LCO 3.1.1.1 SDM*
- *
When is LCO 3.1.1.1 SDM Applicable?
MODES 1 - 5
- LCO 3.1.1.1 SDM*
- *
What must SDM be greater than in MODES 1 -2?
> 1.3 % ∆p
SDM: The instantaneous amount of reactivity by which the reactor is subcritical or would be subcritical from its present condition assuming:
- All RCCAs fully inserted
- Highest reactivity RCCA fully withdrawn
- LCO 3.1.1.1 SDM*
- *
What is the bases for the different regions of the SDM curve in the COLR?
Constant SDM Region (1.3 % ∆p)
Protect against uncontrolled C/D from SLB
Variable SDM Region
Protect against boron dilution accident
- LCO 3.1.1.1 SDM*
- *
When must SDM be verified prior to criticality?
MODE 2 w/ keff < 1
Within 4 hrs prior to criticality
Also performed prior to operations > 5% RTP after refueling.
- LCO 3.1.1.1 SDM*
- *
While in MODES 3-5, SDM must be evaluted once per 24 hrs. Which factors must be taken into consideration?
RCS Boron Concentration
Xenon Concentration
RCCA position
Tavg
Fuel Burnup
- LCO 3.1.1.1 SDM*
- *
What are your ≤ 1 hour action(s) if SDM is not within the limits specified in the COLR?
- LCO 3.1.1.1 SDM*
- Action A*
- *
Initiate Boration to restore SDM [15 min]
LCO 3.1.1.3 MTC
When is LCO 3.1.1.3 MTC Applicable?
BOL (+MTC) Limit
MODES 1-2
EOL (-MTC) Limit
MODES 1-3
- LCO 3.1.3.1 Movable Control Assemblies*
- *
When is LCO 3.1.3.1 Movable Control Assemblies Applicable?
MODES 1 and 2
All S/D and Control Banks shall be OPERABLE AND within ± 12 steps of their group step counter demand position.
- LCO 3.1.3.1 Movable Control Assemblies*
- *
What are your ≤ 1 hour action(s) if ≥ 1 rods inoperable due to being immovable due to friction / mechanical interference or is known to be untrippable?
- LCO 3.1.3.1 Movable Control Assemblies*
- Action A*
- *
- Determine SDM [1 hr]
- LCO 3.1.3.1 Movable Control Assemblies*
- *
What are your ≤ 1 hour action(s) if 1 rod is trippable but inoperable due to something other than being immovable due to friction / mechanical interference OR > ± 12 steps from it’s group counter?
- LCO 3.1.3.1 Movable Control Assemblies*
- Action B*
- *
Power Operation may continue provided:
- Rod restored to OPERABLE status [1 hr]
OR
- Rod declared INOPERABLE [1 hr]
- Remainder of Rods in group aligned to within ± 12 steps on group counter while maintaining rod sequence and insertion limits of COLR [1 hr]
- Thermal power restricted per LCO 3.1.3.6 Control Rod Insertion Limits [1 hr]
OR
- Rod declared inoperable [1 hr]
- Verify SDM [1 hr]
- LCO 3.1.3.1 Movable Control Assemblies*
- *
What are your ≤ 1 hour action(s) if > 1 rod is trippable but inoperable due to something other than being immovable due to friction / mechanical interference?
- LCO 3.1.3.1 Movable Control Assemblies*
- Action D*
- *
Power Operation may continue provided that:
- Remainder of Rods in group aligned to within ± 12 steps on group counter while maintaining rod sequence and insertion limits of COLR [1 hr]
- Thermal power restricted per LCO 3.1.3.6 Control Rod Insertion Limits [1 hr]
- LCO 3.2.1 AFD*
- *
When ≥ 90% RTP, what are your ≤ 1 hour action(s) if AFD is outside the target band?
- LCO 3.2.1 AFD*
- Action A.1*
- *
- Restore AFD to target band [15 min]
OR
- Reduce RTP to < 90% RTP [15 min]
- *
Target band is +5 / -10
- Note:*
- Considered outside target band if ≥ 2 excore instruments indicating outside band.*
- LCO 3.2.1 AFD*
- *
When < 90% RTP but ≥ 50% RTP, what are your ≤ 1 hour action(s) if AFD is outside the target band?
- LCO 3.2.1 AFD*
- Action A.2*
- *
Power operation may continue if:
- Been outside target band ≤ 1 hr during last 24 hrs (Cumulative) [1 : 1 ratio]
- AFD in accepatable region in COLR
Otherwise:
- Reduce RTP < 50% RTP [30 min]
- Reduce Power Range Flux High Trip ≤ 55% RTP [4 hrs]
> 15% RTP but < 50% RTP with AFD outside the target band cumulates time in a 2 min : 1 min penalty ratio.
- Note:*
- Considered outside target band if ≥ 2 excore instruments indicating outside band.*
- LCO 3.2.1 AFD*
- *
When is LCO 3.2.1 AFD Applicable?
MODE 1, > 15 RTP
- LCO 3.2.2 Heat Flux Hot Channel Factor FQ(Z)*
- *
When is LCO 3.2.2 Heat Flux Hot Channel Factor FQ(Z) Applicable?
MODE 1
Peak kW/ft⁄Average kW/ft