book 100 high rise Flashcards
the incident commander is responsible for?
all incident operations,plans and directs overall strategy and control,establishes organizational elements
operations section chief when implemented?
manages all tactical operations involving all primary fire suppression
1st on scene fire company shall?
be fire attack
1st on scene fire company responsibility?
enter building,determine safe ascent,locate the emergency
rescue group manager does?
supervises 1 or more rapid intervention companies
staging managers does?
located 2 floors below the fire,orders supplies and equipment directly from logistics
elevator group does?
searches for unaccounted elevators
ground support/formally stairwell support does
provide transportation of equipment,reports to Support Branch of Logistics,Auxiliary water supply if needed
Base does?
200 ft min,2 companies in base for every 1 company in staging,established by 1st Alarm assignment engineers,reports to logistics
1st alarm assignment is how many companies?
5, 3 engines and 2 trucks 1 bls ra, 1 als ra,
fire company attacking the fire shall?
2 members for fire attack, 2 members stand by,officer in stairwell becomes Division supervisor
lobby reports to?
logistics chief
staging reports to
operations chief
base reports to?
logistics
technical specialist reports to?
planning
how many have been trained as airborne engine companies?
several
base is usually how many feet from the hi rise building?
200ft
base can be implemented beanie first alarm __?
engineers
the command post is usually how many feet from the hi rise building?
200 ft
air operations shall remain __ft from the building and command post?
500 ft
who determines the means of ascent for fire attack?
fire attack captain
it is imperative that company officers have knowledge of __ elevators?
phase 11
when feasible fire attack shall also take which tool aloft?
extra air bottles
in 1974hi rise buildings and newer require a min of how many means of egress per floor?
2
the hi rise occupant program requires floor drills
yearly
hi rise magnetic doors require how many pounds of magnetic pressure to open?
25 pounds
Fire attack do not use the elevator if closer than__floors below the reported floor?
2
outlet orface plate will restrict volume to how many GPM’s at 45 PSI?
200 GPM
who will establish an auxiliary water supply if needed?
ground support
flashover may occur as low as what temperature?
700
stairs shaft ventilation positive pressure shall not exceed how many PSI?
25 PSI
a __” luminous or reflective decal is located in the lower corner of the window that states fire dept. use?
3inches
building built between 1960 and 1974 will have tempered glass on how many sides of the building?
2
when using blower in a hires, place in __is more effective than placing in series?
V
opening top to bottom doors in a hi rise can create__to__MPH airflow
3 to 6 mph
when providing cross ventilation, blowers are effective up to how many floors?
25
phase 11 override phase elevator applies to all elevators__feet and taller?
70
all elevator not automatically recalled lobby area shall be recalled using?
Emergency service switch
after 1985, phase 11 elevator will have a separate __button?
Call Cancel
class 1 standpipe are 4” to 6” risers with outlets that are limited to how many GPM?
500 gpm
class 1 standpipe have 2 1/2” globe valve on every floor except?
first floor
class 11 risers are usually what size?
1 1/2” and 2 1/2”
class 11 standpipe are required on all building 3 or more stories.also required in building 4 or more after?
1983
class 111 6 standpipes inlet are required when there are __ or more risers
3
class 111 inlets are __ GPM per inlet?
250
in 1974 to present hi rise,outlets are set at__?
300
class 1 standpipes are required to cover any portion of the building with a __ foot stream and 100 feet of hose?
30
after 1974 class 111 buildings 75 to 150 have water tanks calibrated for fire flow for__ minutes?
30 minutes
after 1974 class 111 buildings in height above 275 ft in height will have 2” tank refill piping that will refill the tank in __ hours or less?
12 hours
hi rise after 1974, class 111 buildings use PRV when the outlets exceed __ psi?
150 psi
hi rise orfice plates are calibrated at 200 GPM at __PSI?
45 psi
hi rise after 1974 have PRV’s set at __PSI to__PSI?
80 to 125 psi
jockey pumps are usually set__to__ PSI higher than pump starting pressure?
5 to 10 psi
fire pump “time Out Timers” for electric motors are 7 to 10 minutes Diesel are __ minutes?
30
buildings built 1974 to present will have tempered glass on how many sides of the building ?
all
buildings built prior to 1960 were limited to how many many feet in height?
150
what is a plenum?
hidden space
the lox box shall have how many copies of un-plasticized building inventory sheets?
6
helicopters shall remain how far from the building?
500 ft
hoist rescue with a helicopter is limited to 250 feet or __stories below the roof?
20 stories
all new hi rise are what type construction?
1
who is responsible for Dollar loss in a hi rise fire?
A- unit
hi rise buildings are not defined by ?
actual height
base should maintain __for each __company in staging?
2 for 1
lobby shall keep civilian __feet from the building?
200 ft
high rise diesel fire pump shall pump__% of capacity during its acceptance test?
150
if asbestos is found during a hi rise fire overhaul what type of mask shall be worn?
SCBA
what type of hi rise is system is a pig tail not recommended?
dry
when providing ventilation above a hi rise fire, use 2 teams __ floors above?
2
in a hy rise fire one of the most overlooked forcible entry tool is a ?
hayward
in a pre 60 building __ needs to inform Lobby of companies that by-pass lobby?
IC
when companies are working out of different stairwells, what will be their designation?
Division
which 2 channels shall Staging monitor?
Command and Logistics
hi rise command staff includes all of the following?
pio,liaison officer, safety officer
after implemented whom will systems control report to?
logistics
after implemented who will air recon report to?
operations
after implemented, who will search group report?
operations
after implemented who will ground support report to?
logistics
after implemented who will technical support report to?
planning
after implemented whom will medical unit report to?
logistics
air operations shall remain__feet away from the building and command post?
500
who does the rehab unit report to?
medical unit leader
who will establish water to the lobby?
Base
who will establish an auxiliary water supply if needed?
ground support
damaged caused by fire suppression operations used in controlling fire best describes?
indirect
when searching in a hi rise , firefighters shall indicate a search room is complete by?
X with company number on door
if fire attack is unable to extinguish the fire, they should?
protect vertical opens
switching hi rise air handling control is under the control of?
IC
hoist rescue with a helicopter is limited to 250 feet or __ stories below the roof?
20
who is responsible for dollar loss in a hi rise fire?
A-unit
when companies are working out of different stairwells, what will be their designation?
company ID
when hi rise windows are broken, place__in fronton windows opening for safety?
desk
base should maintain__for each __company in staging?
2 for 1
lobby shall keep civilian__feet from the building?
200
when using sound powered headphone, use__per stairwell?
1
time needed for helicopters arrival to the Harbor?
20 minutes
time needed for helicopters arrival to the valley?
5 to 7 minutes
time needed for helicopters arrival to DTLA?
10 to 12 minutes
time needed for helicopters arrival to west LA?
10 minutes