? 3 Flashcards
The LPU-10/P uses a FLU-1/P that incorporates a cell venting capability which eliminates the need for what?
A breather clip.
What color are the LPU-38/P bladders?
Yellow with a black cover.
During which inspection procedure do you not open the life preserver?
Screening.
What type f inspection do you perform on flotation equipment when the equipment status is questionable?
Special.
What is the minimum allowable corrected PSI during the 6 hour leak test of the LPU-10/P?
1.5
What is the acceptable VDC reading during the FLU-9 B/P battery test?
12.0 VDC
During the leak test of the LPU-38/P the initial PSI you need to inflate the bladder to is what?
3.25
During the LPU-38/P leak test what is the min PSI allowed in the bladders to pass the test after at least one hour.
2.5 PSI
What item do you center on top of the last fold after completion of the folding procedure on the LPU-10/P cell?
Oral inflation valve.
When closing the LPU-38/P container using the top side folding procedure, the top should form a fold approximately how man inches wide?
3
When closing the LPU-38/P container, what is the required torque value on the exterior cover screws?
12-15 IN/LBS
When fitting the LPU-10/P to a crew member, where are the containers placed?
Below armpits.
How is the tacking of excess straps on the LPU-38/P secured?
Surgeons knot, followed by a locking knot.
How many primary inflators are on an A-A-50652?
2 singles.
What is the length of the nylon lanyard that is attached to the D ring or waist strap on the adult/child preserver?
10 ft